Print Back
Meter Type
Electromagnetic Flowmeter (Magmeter) has no moving parts, is non-intrusive, and is a highly accurate.

How It Works
The meter works with any media that is electrically conductive (has conductive ions in it). The meter creates a magnetic field and as a conductive fluid passes through the field, the field changes inducing a voltage. As the velocity changes, the voltage changes. The voltage change is picked up by two electrodes that are amplified, conditioned, and sent to a processor to relay the signal to the display or output signal producing a rate and volumetric measurement of flow.
QSE Series 1/2 - 2" Magmeters
Unit of Measure
1 

Model #

Connection

Flow Range

Body Material

Pressure Rating

GPI-QSE05NPTQ9XXXA N/A 1/2" FNPT N/A 0.16 to 10 GPM N/A Noryl® N/A 150 PSIG @ 73 ºF
GPI-QSE07NPTQ9XXXA N/A 3/4" FNPT N/A 0.33 to 20 GPM N/A Noryl® N/A 150 PSIG @ 73 ºF
GPI-QSE10NPTQ9XXXA N/A 1" FNPT N/A 0.67 to 40 GPM N/A Noryl® N/A 150 PSIG @ 73 ºF
GPI-QSE15NPTQ9XXXA N/A 1-1/2" FNPT N/A 1.33 to 80 GPM N/A Noryl® N/A 150 PSIG @ 73 ºF
GPI-QSE20NPTQ9XXXA N/A 2" FNPT N/A 2.5 to 150 GPM N/A Noryl® N/A 150 PSIG @ 73 ºF
GPI-QSE05NPTQBXXXA N/A 1/2" FNPT N/A 0.16 to 10 GPM N/A Noryl® N/A 150 PSIG @ 73 ºF
GPI-QSE07NPTQBXXXA N/A 3/4" FNPT N/A 0.33 to 20 GPM N/A Noryl® N/A 150 PSIG @ 73 ºF
GPI-QSE10NPTQBXXXA N/A 1" FNPT N/A 0.67 to 40 GPM N/A Noryl® N/A 150 PSIG @ 73 ºF
GPI-QSE15NPTQBXXXA N/A 1-1/2" FNPT N/A 1.33 to 80 GPM N/A Noryl® N/A 150 PSIG @ 73 ºF
GPI-QSE20NPTQBXXXA N/A 2" FNPT N/A 2.5 to 150 GPM N/A Noryl® N/A 150 PSIG @ 73 ºF
Unit of Measure
1